ISOCON-6 USERS GUIDE
ISOCON-6
24V AC or DC POWERED
ISOLATING SIGNAL CONVERTER
Whilst every effort has been taken to ensure the accuracy of this document, we
accept no responsibility for damage, injury, loss or expense resulting from errors
or omissions, and reserve the right of amendment without notice.
Industrial Interface
IMO
This document may not be reproduced in any way without the prior written
permission of the company.
February 2002
IIG-010801 Page 1
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - ISOCON-6

ISOCON-6 USERS GUIDE ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure

Page 2 - Page 2 IIG-010801

ISOCON-6 USERS GUIDE 4.1.5 Thermocouple Input Select the range from the table below and set Switch S1 to the required values. SwitchK J R S N E B T

Page 3 - 2. UNPACKING

ISOCON-6 USERS GUIDE 4.1.6 RTD Input Select the range from the table below and set Switch S1 to the required values. Range in °C1234567891011120 to

Page 4 - 3. CONNECTIONS

ISOCON-6 USERS GUIDE 4.1.7 Output Configuration Select the range from the table below and set Switch S3 to the required values. 1 23456 78 910 111

Page 5 - 4. CONFIGURING THE ISOCON

ISOCON-6 USERS GUIDE 5. CALIBRATING THE ISOCON When the unit is shipped the ISOCON will be calibrated for the input and output types and ranges noted

Page 6 - 4.1.1 Voltage Input:

ISOCON-6 USERS GUIDE When the unit is used to convert a thermocouple input it is important when calibrating to ensure that the thermocouple simulator

Page 7

ISOCON-6 USERS GUIDE 7. TROUBLESHOOTING The ISOCON has some built in self diagnostic functions. If the LED on the front panel is flashing then the fa

Page 8

ISOCON-6 USERS GUIDE 8. SPECIFICATIONS ( @ 25°C) Operating Temperature 0 to 55 °C Operating Altitude Sea Level to 2000m Humidity 0-90% RH Power Re

Page 9

ISOCON-6 USERS GUIDE CONTENTS 1. INTRODUCTION ____________________________________ 3 1.1 Hardware Features _________________________________ 3 1.1.1

Page 10 - Switch S2

ISOCON-6 USERS GUIDE 1. INTRODUCTION 1.1 Hardware Features The ISOCON-6 is a universal input Isolating Signal Converter. It can accept virtually eve

Page 11 - 4.1.6 RTD Input

ISOCON-6 USERS GUIDE 3. CONNECTIONS The ISOCON is housed in a compact DIN rail mounting enclosure, with 8 terminals, arranged in 4 rows of 2 terminal

Page 12

ISOCON-6 USERS GUIDE 4. CONFIGURING THE ISOCON !! WARNING ! DO NOT OPEN UNIT OR ADJUST SWITCHES WITH POWER SUPPLY, INPUT OR OUTPUT CONNECTED The

Page 13 - IIG-010801 Page 13

ISOCON-6 USERS GUIDE 4.1.1 Voltage Input: Select the range from the table below and set Switch S1 to the required values. Voltage Range12345678910 1

Page 14 - 6. INSTALLATION

ISOCON-6 USERS GUIDE 4.1.2 Current Input Select the range from the table below and set Switch S1 to the required values. mA Range1234567891011

Page 15 - 7.2 Sensor Failure

ISOCON-6 USERS GUIDE 4.1.3 Millivolt (mV) Input Select the range from the table below and set Switch S1 to the required values. mV Range1

Page 16 - x D x W)

ISOCON-6 USERS GUIDE 4.1.4 Potentiometer Input Select the range from the table below and set Switch S1 to the required values. Potentiometer Input12